Difference between revisions of "Extensions.DiagCom.CreateDiagServiceBySemantic"
Jump to navigation
Jump to search
Line 1: | Line 1: | ||
{{DISPLAYTITLE:OTX '''CreateDiagServiceBySemantic'''}}[[Category:DiagCom]] | {{DISPLAYTITLE:OTX '''CreateDiagServiceBySemantic'''}}[[Category:DiagCom]] | ||
== Classification == | == Classification == | ||
− | {{ClassificationActivity | CreateDiagServiceBySemantic | Creates a diagnostic service through its semantic attribute | [[Term]] | [[Extensions.DiagCom|OTX DiagCom extension]] | [[DiagService related terms]] | [[ | + | {{ClassificationActivity | CreateDiagServiceBySemantic | Creates a diagnostic service through its semantic attribute | [[Term]] | [[Extensions.DiagCom|OTX DiagCom extension]] | [[DiagService related terms]] | [[Core.Actions.Throw.Exception.AmbiguousSemanticException|AmbiguousSemanticException]] | - }} |
== OTL Syntax == | == OTL Syntax == |
Revision as of 08:02, 16 February 2016
Contents
Classification
Name | CreateDiagServiceBySemantic |
Short Description | Creates a diagnostic service through its semantic attribute |
Class | Term |
Extension | OTX DiagCom extension |
Group | DiagService related terms |
Exceptions | AmbiguousSemanticException |
Checker Rules | - |
Standard Compliant | Yes |
OTL Syntax
DiagServiceTerm = DiagCom.CreateDiagServiceBySemantic(ComChanneTerm, StringTerm);
Description
The CreateDiagServiceBySemantic term creates a handle to a diagnostic service, which can be used for further parameterization or for direct ship, see Diagnostic Runtime System. The diagnostic service is a Semantic Attribute selected.
Return Value
The Term returns the value, see table below.
![]()
In OTX, Terms are categorized according to its return data type!
Data Type | Description |
DiagService | Generated Diagnostics Service. |
Properties
Name | Data Type | Class | Default | Cardinality | Description |
ComChannel | ComChannel | Term | - | [1] | Communication Channel. |
Semantic | String | Term | - | [1] | Semantic attribute to classify the diagnostic services (eg: "DEFAULT_FAULTREAD" or "IDENTIFICATION"). |
OTL Examples
DiagCom.ComChannel myComCannel;
DiagCom.DiagService DiagService1;
myComCannel = DiagCom.GetComChannel("LL_AllEmissRelatUDSSyste", null, false);
DiagService1 = DiagCom.CreateDiagServiceBySemantic(myComCannel, "CALIBRATIONREAD");
See also
GetDiagServiceListBySemantic
GetDiagServiceFromResult
GetDiagServiceFromException
GetDiagServiceName
ExecuteDiagService