Extensions.DiagDataBrowsingPlus.GetDbParameterByteLength
Jump to navigation
Jump to search
Contents
Classification
Name | GetDbParameterByteLength |
Short Description | Gets the byte length of the DbParameter |
Class | Term |
Extension | OTX DiagDataBrowsingPlus extension |
Group | DbParameter related terms |
Exceptions | NONE |
Checker Rules | - |
Standard Compliant | Yes |
OTL Syntax
IntegerTerm DiagDataBrowsingPlus.GetDbParameterByteLength(DbParameterTerm dbParameter);
Description
GetDbParameterByteLength returns the byte length of the parameter in the PDU.
The appropriate MVCI system operation is MCDDbParameter::getByteLength
Return Value
The Term returns the value, see table below.
In OTX, Terms are categorized according to its return data type!
Data Type | Description |
Integer | Returns the byte length of the parameter. |
Properties
Name | Data Type | Class | Default | Cardinality | Description |
DbParameter | DbParameter | Term | - | [1..1] | The element addresses the DbParameter (MCDDbParameter) which byte length shall be returned. |
OTL Examples
/// Local Declarations
DiagCom.Result Result;
DiagCom.Response Response;
DiagCom.Parameter Parameter;
DiagDataBrowsingPlus.DbParameter DbParameter;
Integer MyInteger;
/// Flow
[#MetaData(RequestPdu), <#Data>22 2A 19</#Data>]
DiagCom.ExecuteDiagService(DiagCom.CreateDiagServiceByName(DiagCom.GetComChannel("LL_GatewUDS", "EV_GatewLear_006", false), "DiagnServi_ReadDataByIdentMeasuValue"), {Param_RecorDataIdent = "stall current measurement value"}, {}, Result, NULL, false, false);
Response = DiagCom.GetFirstResponse(Result);
Parameter = DiagCom.GetParameterByPath(Response, {"Param_DataRecor", "Param_StallCurreMeasuValue", "Case_MeasuValue", "Param_Ruhes"});
DbParameter = DiagDataBrowsingPlus.GetParameterDbParameter(Parameter);
MyInteger = DiagDataBrowsingPlus.GetDbParameterByteLength(DbParameter);
See also
GetComChannel
CreateDiagServiceByName
ExecuteDiagService
GetFirstResponse
GetParameterByPath
GetParameterDbParameter