Extensions.DiagCom.SetParameterValue
Jump to navigation
Jump to search
Classification
Name | SetParameterValue |
Short Description | Sets a specific value to a Parameter element |
Class | Action |
Extension | OTX DiagCom extension |
Group | DiagService related actions |
Exceptions | OutOfBoundsException TypeMismatchException |
Checker Rules | - |
Standard Compliant | Yes |
OTL Syntax
DiagCom.SetParameterValue(ParameterTerm parameter, Term value);
Description
The OTX SetParameterValue activity sets a specific value to a Parameter element. The value to be set is to be provided as an OTX simple type, an OTX lists or maps or an OTX Quantity
Properties
Name | Data Type | Class | Default | Cardinality | Description |
Parameter | Parameter | Term | - | [1] | This element specifies the parameter which will be set. |
Value | - | Term | - | [1] | This element specifies the value that will be set to the Parameter. Allowed input types are OTX simple types, OTX bytefields, lists and maps and OTX quantities. |
OTL Examples
/// Local Declarations
DiagCom.Request Request1;
DiagCom.Parameter Parameter1;
/// Flow
Request1 = DiagCom.GetRequest(DiagCom.CreateDiagServiceByName(DiagCom.GetComChannel("LL_GatewUDS", "", false), "SinglJob_PostDataSet"));
Parameter1 = DiagCom.GetParameterByPath(Request1, {"IPA_Refer"});
DiagCom.SetParameterValue(Parameter1, &FFFF);
See also
GetComChannel
CreateDiagServiceByName
CreateDiagServiceBySemantic
GetRequest
GetParameterByPath